7.3. Closed-circuit Television Integration
7.3.1. The system shall support closed-circuit television (CCTV) cameras (twisted-
pair type) installed in user-selected locations throughout the installation site
with the installation of Camera Routing Cards CR16 into each SS16.
7.3.2. Cameras shall connect via ports located in each CR16 configured SS16.
7.3.3. Connections between the camera and SS16 port shall be via standard CAT5
cable.
7.3.4. Sixteen cameras shall be supportable by one CR16/SS16 with one live feed
per SS16 back to monitoring equipment.
7.3.5. Cameras shall be configurable to transmit video to designated locations within
the CH1000 installation site.
7.3.6. Cameras shall be installed where indicated by administrative staff.
7.3.7. Each camera port shall be programmable to transmit video upon activation of
programmable inputs, or to transmit video upon command or based on a user
programmable schedule.
7.3.8. Cameras shall transmit video upon activation of programmed inputs such as
call switch, audio level sensors, motion sensors, door contacts, glass break
sensors, or other device providing closed contacts.
7.3.9. Cameras shall transmit video on-demand as result of manual activation via
DA1, or other authorized administrative communication device; PBX
telephone, or wireless telephone.
7.3.10. Video shall be viewable on site administration’s choice of computer monitors
and video monitors, as well as recordable to administration’s choice of media,
e.g., hard drive, time-lapse video recorder.
7.4. Display Administrative Console (DA1)
7.4.1. The DA1 shall be desk-mounted or wall-mounted, and contains a matching
telephone handset with retractable coiled cord and plastic button switches,
with clearly designated touch points. The housing shall be constructed of high
impact, flame retardant, plastic. Wall terminations shall be a RJ-45 modular
telephone type jack.
All Specifications are Subject to Change CareHawk 8